QuantaMesh T7032-IX1
The Next Wave Ethernet Switch for Data Center and Cloud Computing
- EoL Date: 2021/5/15
- 100G Ethernet Switch
- VXLAN
- Multi-Chassis Link Aggregation (MLAG)
- OSPF, BGP4 with ECMP
- Network Automation
The Next Wave Ethernet Switch for Data Center and Cloud Computing The QuantaMesh T7032-IX1 is a high performance and low latency layer 2/3/4 Ethernet switch with 32 100GbE QSFP28 ports in a 1U form factor. Each 100G QSFP28 port can be independently configured to support 10/25/40/50/100GbE speed and can support up to 128 10/25G connections or 64 50G connections via split out cables. Built for infrastructure-as-a-service (Iaas) data center deployment, high performance computing clusters, and financial applications, the QuantaMesh T7032-IX1 – with its very high port density and high performance as well as ultra-low latency characteristic – is idea for demanding workloads and provides optimal TCO. |
Automation With the rapid adoption of cloud computing and the proliferation of big data and parallel calculations, the need for data center network devices is growing exponentially, making network automation a critical factor. Supporting auto installation, RESTful, Ansible and PSME (Pooled System Managment Engine), T7032-IX1 facilities easy deployment to build-up a mass data center with infrastructure-as-a-Service (IaaS). |
Virtualization Network virtualization is becoming an important topic of data centers. QuantaMesh T7032-IX1 offers a hardware-based VXLAN to support virtual machine mobility. Not limited by 4K VLANs, VXLAN enables network scale-out across L3 subnets and can support up to 16.7M possible virtual networks. |
High Availability The QuantaMesh T7032-IX1 is designed for high availability from both hardware and software perspectives. The key features include:
|
Certification
Physical ports | |
---|---|
Port configuration |
32 QSFP28 ports
|
Management Port |
Out-of-band management port (RJ-45, 10/100/1000BASE-T)
|
Console Port |
1 (RJ-45)
|
USB |
1 (v2.0)
|
Performance | |
---|---|
Switching capacity |
6.4Tbps
|
Maximum forwarding rate |
3.3Bpps
|
Latency |
<450ns
|
Major Components | |
---|---|
ASIC |
Broadcom StrataXGS Tomahawk
|
CPU |
Intel ATOM Processors
|
Memory |
8GB DDR3/ECC
|
Storage |
32G SSD
|
Layer 2 Features | |
---|---|
Switching Mode |
Store-and-Forward
|
Spanning Tree |
802.1w
802.1s Auto Edge |
VLAN |
IEEE 802.1Q Tagged Base
Port-Based QinQ (802.1ad) |
Storm Control |
Broadcast
Unknown Multicast DLF (Unknown Unicast) |
IGMP Snooping |
v1/v2/v3
v1/v2 Querier Immediate Leave |
MLD Snooping v1/v2 | |
Link Aggregation |
802.3ad with LACP
Static Trunk Unicast/Multicast Traffic Balance over Trunking Port LACP Fallback |
Link State Tracking | |
Port Backup | |
Loopback Detection | |
Private VLAN | |
Link Debounce |
QoS Features | |
---|---|
Scheduling for priority queue |
WRR, Strict, Hybrid
|
COS |
802.1p
IP TOS precedence DSCP |
DiffServ | |
iSCSI optimization |
Security Features | |
---|---|
Static and dynamic port security (MAC-based) | |
802.1x (MD5, MS-CHAPv2) |
MAC-based
Port-based Auto VLAN assignment Guest VLAN Unauthenticated VLAN |
Access Control List |
L2/L3/L4
|
IPv4/IPv6 ACL |
L3/L4
|
RADIUS/TACACS+ |
Authentication, Authorization, Accounting
|
SSH V2.0 | |
User Name and Password |
Local Authentication
Remote Authentication via RADIUS/TACACS+ AAA |
Management IP Filtering |
SNMP
Telnet SSH |
SSH Public Key Authentication | |
IP Source Guard | |
Dynamic ARP inspection (DAI) | |
DHCP Snooping |
IPv4
IPv6 |
Control Plane Policing / CoPP | |
Service Prohibit Access | |
Signed Firmware Image | |
Role Base Access Control (RBAC) |
Layer 3 Features | |
---|---|
IP Multinetting/CIDR | |
/31 subnets | |
Proxy ARP | |
Static route |
IPv4
IPv6 |
OSPF v2/v3 | |
ECMP | |
BGP4 | |
IGMP v1/v2/v3 | |
PIM-SM/-SM6 | |
MLD v1/v2 | |
Policy-Based Routing (PBR) | |
BFD | |
VRF Lite | |
Black Hole Detection (BHD) | |
VRRP v3 | |
IP SLA |
Management Features | |
---|---|
Industrial command-line interface | |
CLI filtering | |
CLI scheduler | |
SSH | |
Software Update |
TFTP
SCP SFTP |
Configuration download/upload |
TFTP
SCP SFTP |
Dual Images | |
SNMP v1/v2c/v3 | |
SNMP inform v2 | |
RMON1 Groups: 1, 2, 3, 9 | |
DHCP client | |
DHCP relay (VxLAN environment supported) | |
EVENT / Error log | |
Remote PING | |
Traceroute | |
NTPv4 | |
LLDP |
802.1ab
802.MED Potential error detection |
UDLD | |
Port mirroring |
SPAN
RSPAN |
sFlow v5 | |
Email alerting |
SMTP
|
Error-Disable Recovery |
IPv6 Management | |
---|---|
IPv4/IPv6 Dual Protocol Stack | |
ICMPv6 | |
ICMPv6 Redirect | |
IPv6 Neighbor Discovery | |
Stateless Autoconfiguration | |
Manual Configuration | |
DHCPv6 client/relay | |
SNMP over IPv6 | |
SSH over IPv6 | |
IPv6 DNS Resolver | |
IPv6 RADIUS | |
IPv6 TACACS+ | |
IPv6 Syslog | |
IPv6 TFTP |
High Availability | |
---|---|
Multi-Chassis Link Aggregation (MLAG) |
L2 Unicast/Multicast
L3 Unicast RSTP/MSTP VXLAN |
In-Service Software Upgrade (ISSU) |
Data Center Features | |
---|---|
Priority-based Flow Control (802.1Qbb) | |
DCBX |
DCBX for ETS
DCBX for PFC PCBX for Application Priority |
FCoE Initiation Protocol (FIP) snooping | |
RoCEv1/v2 |
Automation | |
---|---|
Auto installation | |
RESTful API | |
Ansible | |
NETCONF/RESTCONF |
Virtualization Features | |
---|---|
VxLAN Switching/Routing | |
BGP-EVPN Route Support |
SDN | |
---|---|
OpenFlow v1.3 |
Mechanical | |
---|---|
Dimension (HxWxD) |
44 x 440 x 508mm
|
Weight |
9.27kg (NET)
|
Environmental Specifications | |
---|---|
Operating temperature |
0~45°C
|
Operating humidity |
90% maximum relative humidity
|
Power | |
---|---|
PSU |
100~240VAC, 50/60Hz
|
Power consumption |
378 watts
|
Safety | |
---|---|
Safety |
UL, cUL
|
EMC | |
---|---|
EMC |
CE, FCC, VCCI, CCC
|
RoHS | |
---|---|
RoHS |
Reduction of Hazardous Substances (RoHS) 6
|
Supported Optics and Cables | |
---|---|
Supported Optics and Cables |
DAC cable (QSFP+): 1m, 3m, and 5m
DAC cable (QSFP+, fan-out): 1m, 3m, and 5m DAC cable (QSFP28): 1m, 3m, and 5m DAC cable (QSFP28, fan-out): 3m AOC cable (QSFP+, 850nm, MMF): 7m and 10m AOC cable (QSFP28, 850m, MMF): 1m, 3m, 5m, and 10m 40G optic (QSFP+, MPO, 850nm, MMF): 40GBASE-SR4 40G optic (QSFP+, LC, 1310nm, SMF): 40GBASE-LR4 100G optic (QSFP28, MPO, 850nm, MMF): 100GBASE-SR4 100G optic (QSFP28, MPO, 1310nm, SMF): 100GBASE-PSM4 100G optic (QSFP28, LC, 1310nm, SMF): 100GBASE-LR4 |
Ordering Information | |
---|---|
Ordering Information |
T7032-IX1 (1IX1UZZ0STM) Front to Back, with Rail Kit
T7032-IX1 (1IX1UZZ0STN) Back to Front, with Rail Kit PSU - Red (1HY9ZZZ071Y) (F-2-B, AC, 750W) PSU - Blue (1HY9ZZZ0720) (B-2-F, AC, 750W) FAN Module (1HY9ZZZ0721) (F-2-B) FAN Module (1HY9ZZZ0722) (B-2-F) |
Installation / Setup Tips (3)
- 1. [Switch] Can I replace the power supply unit (PSU) and fan to a different direction airflow by myself?
- 2. [Switch] The redundant power supply unit (PSU) in QuantaMesh Switch.
- 3. [Switch] What can I do if I forget the username/password of my QuantaMesh Ethernet Switch?
- 1. [Switch] Are QuantaMesh Network OS (QNOS) license node locked?
- 2. [Switch] What is SDN-ready QuantaMesh Ethernet Switch?
- 3. [Switch] What is included in the QuantaMesh Network Operating System (QNOS)?
- 4. [Switch] What is the End-of-Life policy of a QuantaMesh Switch?
- 5. [Switch] What is the QuantaMesh Ethernet Switch?
- 6. [Switch] Which items are included in the package of a QuantaMesh Switch?

ITOCHU Techno-Solutions Corporation - Reseller / System Integrator
3-2-5 Kasumigaseki, Chiyoda-ku, Tokyo 100-6080 JAPAN
http://www.ctc-g.co.jp/en/index.html
Phone +81-3-6203-5000

Networld Corporation - Distributor
101-0051 東京都千代田区神田神保町2-11-15 住友商事神保町ビル
http://www.networld.co.jp/product/quanta
Phone 03-5210-5080

NEC Networks & System Integration Corporation - Reseller / System Integrator
Iidabashi First Tower, 2-6-1 Koraku, Bunkyo-ku, Tokyo 112-8560, Japan
Phone 81-3-6699-7584

Mitsui E&S Systems Reseach Inc. - Reseller / System Integrator
1-3-D-9 Makuhari Techno Garden Nakase, Mihama-ku, Chiba-shi, Chiba-Pref.261-8501, Japan
https://www.msr.co.jp/english/index.html
Phone +81-565-35-3781

Japan Network Storage Laboratory Inc. - Distributor
AIOS711, 1-11-1 Nishi-Gotanda, Shinagawa-Ku, Tokyo Japan 141-0031
Phone 81-3-64203530